SCA=Single Connector Attachment
Drive connector: AMP Champ 557613-1 or AMP Champ 557114-5
Cable connector: AMP Champ 2-557103-1 or AMP Champ 2-557101-1
Pin | Name | Dir | Description |
---|---|---|---|
1 | 12V | +12 VDC | |
2 | 12V | +12 VDC | |
3 | 12V | +12 VDC | |
4 | 12V | +12 VDC | |
5 | 3.3V | +3.3 VDC | |
6 | 3.3V | +3.3 VDC | |
7 | -DB(11) | Data Bus 11 | |
8 | -DB(10) | Data Bus 10 | |
9 | -DB(9) | Data Bus 9 | |
10 | -DB(8) | Data Bus 8 | |
11 | -I/O | Input/Output | |
12 | -REQ | Request | |
13 | -C/D | Control/Data | |
14 | -SEL | Select | |
15 | -MSG | Message | |
16 | -RST | Reset | |
17 | -ACK | Acknowledge | |
18 | -BSY | Busy | |
19 | -ATN | Attention | |
20 | -P_CRCA | ? | |
21 | -DB(7) | Data Bus 7 | |
22 | -DB(6) | Data Bus 6 | |
23 | -DB(5) | Data Bus 5 | |
24 | -DB(4) | Data Bus 4 | |
25 | -DB(3) | Data Bus 3 | |
26 | -DB(2) | Data Bus 2 | |
27 | -DB(1) | Data Bus 1 | |
28 | -DB(0) | Data Bus 0 | |
29 | -DB(P1) | ? | |
30 | -DB(15) | Data Bus 15 | |
31 | -DB(14) | Data Bus 14 | |
32 | -DB(13) | Data Bus 13 | |
33 | -DB(12) | Data Bus 12 | |
34 | 5V | Ground (Signal) | |
35 | 5V | Ground (Signal) | |
36 | 5V CHARGE | Ground (Signal) | |
37 | SPINDLE SYNC | ? | Spindle Sync |
38 | RMT_START | ? | Remote Start |
39 | SCSI ID (0) | SCSI ID Bit 0 | |
40 | SCSI ID (2) | SCSI ID Bit 2 | |
41 | 12V GROUND | +12 VDC Ground | |
42 | 12V GROUND | +12 VDC Ground | |
43 | 12V GROUND | +12 VDC Ground | |
44 | MATED 1 | ? | |
45 | 3.3V CHARGE | +3.3 VDC Charge | |
46 | DIFFSNS | Differential Sense | |
47 | +DB(11) | Data Bus 11 | |
48 | +DB(10) | Data Bus 10 | |
49 | +DB(9) | Data Bus 9 | |
50 | +DB(8) | Data Bus 8 | |
51 | +I/O | Input/Output | |
52 | +REQ | Request | |
53 | +C/D | Control/Data | |
54 | +SEL | Select | |
55 | +MSG | Message | |
56 | +RST | Reset | |
57 | +ACK | Acknowledge | |
58 | +BSY | Busy | |
59 | +ATN | Attention | |
60 | +P_CRCA | ? | |
61 | +DB(7) | Data Bus 7 | |
62 | +DB(6) | Data Bus 6 | |
63 | +DB(5) | Data Bus 5 | |
64 | +DB(4) | Data Bus 4 | |
65 | +DB(3) | Data Bus 3 | |
66 | +DB(2) | Data Bus 2 | |
67 | +DB(1) | Data Bus 1 | |
68 | +DB(0) | Data Bus 0 | |
69 | +DB(P1) | ? | |
70 | +DB(15) | Data Bus 15 | |
71 | +DB(14) | Data Bus 14 | |
72 | +DB(13) | Data Bus 13 | |
73 | +DB(12) | Data Bus 12 | |
74 | MATED 2 | ? | |
75 | 5V GROUND | +5 VDC Ground | |
76 | 5V GROUND | +5 VDC Ground | |
77 | ACTIVE LED OUT | ? | |
78 | DLYD_START | ? | |
79 | SCSI ID (1) | SCSI ID Bit 1 | |
80 | SCSI ID (3) | SCSI ID Bit 3 |
5: RESERVED/NC 6: RESERVED/NC 20: -DB(P0) 36: 5 VOLT 44: 12 V GROUND 45: RESERVED/NC 46: RESERVED/NC 74: 5 V GROUND
Note: Direction is Device relative Bus (other Devices).
Contributor: Joakim Ögren
Source:
SCA SFF-8015 Draft Rev 3.1
Copyright © The Hardware Book Team 1996-2001.
May be copied and redistributed, partially or in whole, as appropriate.